Our Industrial Temperature Transmitter converts temperature sensor signals into electrical outputs for industrial monitoring and control systems. It is commonly used in power plants, chemical processing facilities, oil and gas pipelines and automated production lines. It can be installed with a new temperature sensor or added to an existing measurement point.
The transmitter receives a signal from a thermocouple or RTD and converts it into a standard output that can be read by PLC, DCS and other control equipment. We offer integrated sensor-transmitter assemblies as well as separate transmitter modules. Optional communication functions are available for compatible models, allowing users to configure the instrument through supported control or maintenance systems.
Core Advantages
Direct 4–20 mA conversion: The transmitter converts weak thermocouple or RTD signals at the measurement point, reducing the need for separate signal conversion equipment in the control room.
Long-distance signal transmission: Standard current output supports transmission over distances of up to 1,000 meters under suitable cable and loop conditions.
Thermocouple compensation: The thermocouple module incorporates cold-junction compensation and nonlinear correction to process the sensor signal.
Sensor fault indication: Configurable fault outputs of ≤3.8 mA or ≥21 mA follow the specified NAMUR NE43 signaling approach, helping control systems identify sensor faults.
Flexible system integration: Integrated and separate transmitter configurations support both new installations and upgrades to existing measurement points.


Applications
- PLC and DCS temperature monitoring systems.
- Petrochemical process pipelines and reactors.
- Power plant boiler and steam temperature measurement.
- Industrial automation and production lines.
- Existing temperature measurement points requiring 4–20 mA signal conversion.
OEM/ODM Customization
We supply Industrial Temperature Transmitter assemblies according to the customer's sensor and control system requirements. Customization includes thermocouple or RTD input type, measuring range, output signal, transmitter accuracy, HART communication, terminal enclosure and mounting structure. We offer integrated sensor-transmitter products and independent plug-in modules. Explosion-proof configurations can also be selected according to the application.


Quality Control
Our inspection process covers sensor input compatibility, transmitter output accuracy, power supply performance, electrical connections and enclosure assembly. Each finished unit undergoes relevant signal and functional checks before shipment. Our group operates CNAS-accredited testing laboratories and provides product documentation according to the confirmed technical configuration.
Product Specifications
|
Parameter |
Integrated Thermocouple (WRNB/SBWR) |
Integrated RTD (WZPB/SBWZ) |
|
Compatible Sensing Element |
K, E, J, T, N, S, R, B thermocouples |
Pt100, Pt1000, Cu50 RTDs |
|
Temperature Range |
-200°C to 1600°C |
-200°C to 500°C |
|
Output Signal |
2-wire, 4–20 mA DC (optional HART protocol) |
2-wire, 4–20 mA DC (optional HART protocol) |
|
Supply Voltage |
DC 12–36 V (24 V nominal) |
DC 12–36 V (24 V nominal) |
|
Transmitter Accuracy |
0.2% FS / 0.5% FS, optional |
0.2% FS / 0.5% FS, optional |
|
Load Capacity |
Maximum 600 Ω at 24 V supply |
Maximum 600 Ω at 24 V supply |
|
Fault Alarm |
Open-circuit/short-circuit output ≤3.8 mA or ≥21 mA (NAMUR NE43) |
Open-circuit/short-circuit output ≤3.8 mA or ≥21 mA (NAMUR NE43) |
|
Ambient Temperature |
Standard: -25°C to 80°C; explosion-proof: -20°C to 70°C |
Standard: -25°C to 80°C; explosion-proof: -20°C to 70°C |
|
Ingress Protection Rating |
IP65 (standard version); IP65 (flameproof version) |
IP65 (standard version); IP65 (flameproof version) |
|
Explosion Protection Rating |
Ex d IIB T4 / Ex d IIC T6 (flameproof); Ex ia (intrinsically safe) |
Ex d IIB T4 / Ex d IIC T6 (flameproof); Ex ia (intrinsically safe) |
|
Key Advantages |
Eliminates the need for extension/compensating cables, supports interference-resistant remote signal transmission, simplifies wiring with a 2-wire configuration |
Eliminates the need for extension/compensating cables, supports interference-resistant remote signal transmission, simplifies wiring with a 2-wire configuration |
|
Applicable Standards |
IEC 60584, GB/T 16839, NAMUR NE43 |
IEC 60751, GB/T 30121, NAMUR NE43 |
|
Warranty Period |
18 months |
18 months |
FAQ
Q: What is the main function of an industrial temperature transmitter?
A: It converts a temperature sensor's original millivolt or resistance signal into a standardized electrical output, commonly 4–20 mA, for industrial monitoring and control systems.
Q: Can the transmitter work with an existing RTD or thermocouple?
A: Yes. Separate transmitter modules are available for compatible existing sensor assemblies, subject to input type, installation dimensions and electrical requirements.
Q: Is HART communication available?
A: Yes. HART communication is an optional configuration for compatible transmitter models.
Hot Tags: industrial temperature transmitter, China industrial temperature transmitter manufacturers, suppliers, factory, digital panel meter, digital temperature instrument, low temperature meter, process temperature controller, Surface Thermocouples and Surface RTDs, Wear Resistant Thermocouple and Abrasion Resistant RTD