Cables for Electrical Equipment

Our cables for electrical equipment cover four product groups: shielded computer cables, universal control cables, compensation wires and high-temperature resistant cables. Selection depends on the signal or control function, rated voltage, conductor size, core or pair count, insulation material, operating temperature and required protection structure.

 
  • Shielded Computer Cable
    DCS distributed control systems, PLC field buses, industrial computers, and precision instrument signal transmission carry very weak signals. These include millivolt-level thermocouple signals, 4-20mA analog signals, and RS485 digital...
    view more
  • Universal Control Cable
    Power plants, chemical plants, metallurgical workshops, and municipal automation systems rely heavily on signal transmission. Switches, 4-20mA analog signals, and equipment control instructions travel through cables between PLCs, DCS,...
    view more
  • Compensation Wire
    Thermocouples are among the most common temperature sensors in industry. But they have a fundamental limitation. The reference junction (cold junction) temperature must stay constant.
    view more
  • High Temperature Resistant Cable
    Steel mills, heat treatment furnaces, petrochemical high-temperature pipelines, glass melting furnaces, and nuclear reactor areas share a common challenge. Ordinary cable insulation softens, cracks, or melts under sustained high...
    view more
 

Product Range

Product Type Main Application Key Selection Factors
Shielded Computer Cable DCS, PLC fieldbus, industrial computers and precision instruments Signal type, conductor cross-section, pair count and shielding structure
Universal Control Cable Control signal transmission between PLCs, DCS systems, frequency converters and field actuators Rated voltage, core count, conductor size, insulation and shielding
Compensation Wire Thermocouple extension and temperature measurement signal transmission Thermocouple type, conductor alloy, insulation temperature rating and pair count
High Temperature Resistant Cable Motors, pumps, furnaces, ovens, metallurgical equipment and high-temperature industrial installations Insulation material, temperature rating, electrical requirements and installation environment

Shielded Computer Cable – DJ Series

DJ series shielded computer cables are used for signal transmission in DCS, PLC fieldbus, industrial computer and precision instrument systems. They can be selected for thermocouple millivolt signals, 4–20 mA analog signals and RS485 digital signals.

Item Available Specifications or Configurations
Conductor cross-section 0.5, 0.75, 1.0 and 1.5 mm²
Pair count 1–24 pairs
DJYPV PE insulation, individual copper tape shielding and PVC sheath
DJYPVP PE insulation, individual copper tape shielding, overall copper wire braided shielding and PVC sheath
DJYPV22 PE insulation, individual copper tape shielding, steel tape armoring and PVC sheath
DJYPVP22 Individual copper tape shielding, overall copper wire braided shielding and steel tape armoring
WDZ-DJYYP Low-smoke halogen-free flame-retardant configuration
WDZN-DJYYP Low-smoke halogen-free fire-resistant configuration

For signal circuits exposed to electrical interference, the shielding structure should be selected according to the installation environment and system requirements. The available configurations include individual copper tape shielding, overall copper wire braided shielding and steel tape armoring.

The listed inspection items include working capacitance, inductance-to-resistance ratio and shielding coefficient.

Universal Control Cable – KVV Series

Universal control cables transmit control signals between PLCs, DCS systems, frequency converters and field actuators. The KVV series is available in PVC and XLPE insulation configurations, as well as shielded, armored and flexible constructions.

Item Available Specifications or Configurations
Rated voltage 450/750 V
Core count 4–61 cores
Conductor cross-section 0.5–2.5 mm²
PVC series operating temperature 70°C
XLPE series operating temperature 90°C
KVV PVC insulation and PVC sheath, unshielded
KVVP PVC insulation and PVC sheath, overall copper wire braided shielding
KVVP2 PVC insulation and PVC sheath, overall copper tape shielding
KVVP22 PVC insulation and PVC sheath, copper wire braided shielding and steel tape armoring
KYJV XLPE insulation and PVC sheath, unshielded
KYJVP XLPE insulation and PVC sheath, copper wire braided shielding
WDZ-KYJYP Low-smoke halogen-free flame-retardant configuration
WDZN-KYJYP Low-smoke halogen-free fire-resistant configuration
KCPR Flexible control cable with rubber sheath; operating temperature 60°C

For shielded models, the listed copper wire braid shielding density is at least 80%. The choice between unshielded, braided-shielded, copper-tape-shielded and armored constructions should be based on electromagnetic interference, mechanical protection and installation conditions.

Compensation Wire

Compensation wires are used to extend thermocouple circuits and transmit temperature measurement signals. The conductor combination must match the thermocouple type used in the measuring system; compensation wire is not a substitute for general-purpose power cable.

Thermocouple Type Compensation Wire Code Conductor Combination
K KC NiCr / NiSi
S SC Copper / copper-nickel
B BC Copper / copper
E EC NiCr / copper-nickel
T TC Copper / copper-nickel
J JC Iron / copper-nickel
Item Available Specifications or Options
Conductor cross-section 0.5, 1.0, 1.5 and 2.5 mm²
Pair count 1, 2 or 3 pairs
PVC insulation 70°C
XLPE insulation 90°C
FEP insulation 200°C
Additional configurations Copper wire braided shielding, steel tape armoring and low-smoke halogen-free options

Each batch undergoes thermoelectric characteristic comparison against standard thermocouples. Specify the thermocouple type and insulation temperature requirement when selecting a compensation wire.

High Temperature Resistant Cable

High-temperature cable selection depends on the insulation material and its stated temperature rating. The following options cover different operating environments and equipment requirements.

Insulation or Cable Type Stated Temperature Rating Typical Models or Applications
XLPE 90°C YJV, KYJV and WDZ-YJY; power distribution and control
EPR 125°C Motor lead and marine cable applications, including motors and pumps in humid environments
Silicone rubber 180°C YGCP and KGG; furnaces, ovens and moving metallurgical equipment
FEP 200°C YFVP, KFVP, DJFFP and KCF; high-temperature industrial and petrochemical applications
PFA 260°C Special high-temperature instrumentation cable for high-temperature or corrosive environments
Magnesium oxide (MI) 950–1000°C fire-exposure resistance Emergency fire-protection and special safety applications

The stated low-temperature rating for silicone rubber and FEP configurations is -60°C. Tinned stranded copper conductors and tinned copper braided shielding are listed construction features.

Important temperature distinction: The 950–1000°C figure for MI cable refers to fire-exposure resistance. It is not a continuous operating temperature rating. Confirm the required fire-resistance test conditions and cable configuration for the intended application.

Standards and Quality Inspection

The product information lists the following standards and inspection items for the corresponding cable groups. The applicable standard should be confirmed against the selected model and construction.

Product Group Standards Listed Inspection or Verification Items
Shielded Computer Cable GB/T 9330; JB/T 10696 Working capacitance, inductance-to-resistance ratio and shielding coefficient
Universal Control Cable GB/T 9330; IEC 60227 Conductor resistance, insulation resistance and voltage withstand
Compensation Wire GB/T 4989; IEC 60584 Thermoelectric characteristic comparison against standard thermocouples
High Temperature Resistant Cable GB/T 12706; GB/T 9330; GB/T 4989; IEC 60331 Confirm applicable test requirements according to cable type and intended service

Product-specific test reports and compliance documents should be confirmed for the selected model rather than assumed to apply to every cable in the range.

Customization and Supply Capabilities

Non-standard cable requirements can be submitted for technical and production assessment. A group cable catalogue also states that unlisted control cable models can be produced to customer requirements. The feasibility of a requested construction, material combination or specification should be confirmed before quotation.

The group’s manufacturing infrastructure includes specialized workshops, automated production lines, an R&D center, digital manufacturing systems and intelligent warehousing and logistics. The group also reports two CNAS-accredited testing laboratories. These are group-level capabilities and should not be interpreted as a claim that every cable model is tested in those laboratories.

Request a Cable Quotation

To help identify a suitable cable construction, send the product type or model, rated voltage where applicable, conductor cross-section, core or pair count, insulation material, required shielding or armoring structure and estimated order quantity.

If the model is not yet confirmed, you can provide a sample photo, cable marking or equipment connection requirements for an initial product assessment.

As one of the most professional cables for electrical equipment manufacturers and suppliers in China, we're featured by quality products and good service. Please feel free to wholesale bulk customized cables for electrical equipment made in China here from our factory. Welcome to contact us for pricelist.

High Temperature Resistant Cable, Shielded Computer Cable, Universal Control Cable
Send Inquiry