Flow Instruments for Industrial Process Measurement

As an industrial flow instrument manufacturer in China, Anhui Tiankang Group supplies flowmeters for measuring liquid, gas and steam flow in industrial process systems. The product range covers electromagnetic, vortex, turbine, differential pressure, variable area and ultrasonic flow measurement. Different measuring principles, installation structures and signal configurations are available for different operating conditions.

For industrial plants, equipment integration and distribution, flowmeter selection depends on the measured medium, pipeline size, flow range, operating pressure and temperature, required accuracy, installation conditions and signal interface.

 
  • Multi-principle Flow Meter
    Our Multi-principle flow meter range covers several industrial flow measurement technologies, including electromagnetic, vortex, turbine, differential pressure, variable area and ultrasonic flow meters. These instruments are used in...
    view more
  • Industrial Turbine Flow Meter
    Our Industrial Turbine Flow Meter is designed for flow measurement of clean liquids and gases in industrial pipelines, fuel systems, chemical processing facilities and utility networks. It is commonly selected for applications requiring...
    view more
  • Digital Vortex Flow Meter
    Our Digital Vortex Flow Meter is designed for flow measurement in steam distribution networks, compressed air systems, natural gas pipelines and industrial liquid transportation lines. It is used in factories, power plants, heating...
    view more
  • Electromagnetic Sewage Flow Meter
    Our Electromagnetic Sewage Flow Meter is designed to measure the flow rate of electrically conductive liquids in wastewater treatment plants, drainage networks, chemical production lines and industrial water systems. It is suitable for...
    view more
  • Electromagnetic Digital Flow Meter
    Wastewater, slurry, chemical acids and alkalis, and seawater present a challenge for traditional mechanical flow meters. These fluids cause wear, blockage, or excessive pressure drops. Anhui Tiankang's electromagnetic digital flow meter...
    view more
  • Vortex Water Flow Meter
    Steam metering, compressed air monitoring, and natural gas transmission all require a flow meter that handles multiple media types. The instrument needs a simple structure with low pressure loss and long-term reliability.
    view more
  • Stainless Steel Turbine Flow Meter
    Clean liquid flow measurement in oil, solvent, and alcohol applications demands exceptional accuracy. Even small measurement errors can cost significant money in trade settlements. Anhui Tiankang's stainless steel turbine flow meter (LW...
    view more
  • High-quality Flow Meter
    Flow meters are among the most important instruments in industrial process control, energy management, and trade settlement. Different flow meter technologies suit different media, pipe sizes, accuracy requirements, and operating...
    view more
 

Product Types and Applications

Flowmeter Type Available Models Typical Applications
Electromagnetic Flowmeter LD, LDF, LDW Conductive liquids, wastewater, slurry, mineral pulp, acids, alkalis and seawater
Vortex Flowmeter LU, LUF, LUW, LUP Clean liquids, gases and steam
Turbine Flowmeter LWGY, LWQ Clean liquids and gases, including water, light oil, organic solvents, compressed air and natural gas

Electromagnetic flowmeters measure conductive liquids and have no moving measuring parts in the flow path. Lining and electrode materials can be selected according to the liquid composition, corrosion requirements and operating temperature.

Vortex flowmeters are used for measuring clean liquids, gases and steam. The LUP configuration incorporates temperature and pressure sensors for mass flow or standard volume flow calculation.

Turbine flowmeters are designed for clean liquid or gas applications. They are suitable for flow measurement where the medium and operating conditions meet the requirements of the selected model. Liquid turbine installations require an upstream filter to protect the measuring element.

Differential pressure, variable area (rotameter) and ultrasonic flowmeters are also included in the product range. Their model and configuration selection should be based on the specific application requirements.

Flowmeter Specifications and Configuration

Electromagnetic Flowmeters

Electromagnetic flowmeters are available in LD, LDF and LDW models, covering integral, remote and insertion installation structures.

Specification LD / LDF LDW
Installation Type Integral or remote Insertion
Nominal Diameter DN10–DN2000 DN300–DN2000
Accuracy ±0.5% or ±1.0% ±1.5%
Medium Conductivity ≥5 μS/cm ≥5 μS/cm
Pressure Rating PN10 / PN16 / PN25 / PN40 PN10 / PN16
Power Supply AC 220V / DC 24V AC 220V / DC 24V
Output Signals 4–20 mA, pulse, RS485, HART 4–20 mA, pulse, RS485, HART

The wetted material configuration should match the measured liquid and operating temperature:

  • Lining: Rubber for temperatures up to 70°C; PTFE, F46 or PFA for temperatures up to 180°C.
  • Electrodes: 316L stainless steel, titanium, Hastelloy or tantalum.
  • Protection: IP65 for integral construction; IP68 for remote sensor configurations.
  • Optional configurations: Ex d IIC T6 explosion-proof design and ANSI 150# flange connection.

Electromagnetic flowmeters are suitable for conductive liquids such as wastewater, slurry, mineral pulp, acids, alkalis and seawater. The medium conductivity must be at least 5 μS/cm. They are not suitable for non-conductive liquids, oils or gases.

Vortex Flowmeters

Vortex flowmeters are available in LU, LUF, LUW and LUP configurations. Integral, remote and insertion structures accommodate different pipeline installation requirements.

Specification LU / LUF LUW
Installation Type Integral or remote Insertion
Nominal Diameter DN15–DN300 DN300–DN2000
Accuracy ±1.0% for liquids; ±1.5% for gas and steam ±1.5%
Standard Temperature Range -40°C to 120°C -40°C to 120°C
Pressure Rating PN16 / PN25 / PN40 PN16
Power Supply DC 24V DC 24V

For high-temperature steam applications, a high-temperature configuration is available for operating temperatures up to 350°C.

The LUP model incorporates temperature and pressure sensors for mass flow or standard volume flow calculation. Output options include 4–20 mA, pulse, RS485 and HART.

Integral construction is rated IP65. For remote configurations, the sensor protection rating is IP67 and the converter protection rating is IP65. Ex d IIC T6 explosion-proof configuration is optional.

Vortex flowmeters are intended for clean, single-phase liquids, gases and steam. They are not recommended for highly viscous, crystallizing or heavily particle-laden media.

Turbine Flowmeters

Turbine flowmeters are available for liquid and gas measurement. LWGY models are designed for liquids, while LWQ models are designed for gases.

Specification LWGY Liquid Turbine LWQ Gas Turbine
Nominal Diameter DN4–DN200 DN25–DN300
Accuracy Options ±0.2%, ±0.5%, ±1.0% ±0.5%, ±1.0%, ±1.5%
Temperature Range -20°C to 120°C -20°C to 80°C
High-Temperature Option Up to 150°C —
Pressure Rating PN16 / PN25 / PN40 PN16 / PN25 / PN40
Output Options Pulse, 4–20 mA, RS485 Modbus Pulse, 4–20 mA, RS485 Modbus
Power Supply DC 24V or built-in battery DC 24V or built-in battery

The liquid turbine series offers a standard rangeability of 10:1, with a 20:1 wide-range option. Gas turbine configurations vary by model.

Suitable liquid media include water, light oil, organic solvents and alcohol. Gas applications include compressed air, nitrogen, natural gas and town gas.

An upstream filter is required for liquid turbine installations. A typical filtration precision is better than 100 μm. Filter selection should also consider the medium and operating conditions.

Materials, Outputs and Customization

Flowmeter configuration should be selected according to the medium, operating conditions, pipeline connection and control system requirements.

Wetted Materials and Medium Compatibility

For electromagnetic flowmeters, lining and electrode materials can be selected to suit liquid composition and corrosion requirements. Rubber, PTFE, F46 and PFA lining options cover different temperature and chemical compatibility requirements. Electrode options include 316L stainless steel, titanium, Hastelloy and tantalum.

Installation and Structural Options

  • Integral or remote construction for applicable electromagnetic and vortex models.
  • Insertion construction for large-diameter pipelines.
  • Flange connections and pressure ratings selected according to pipeline requirements.
  • High-temperature vortex configurations for steam applications.
  • Explosion-proof configurations where required by the installation environment.

Signal and Power Configuration

Available signal options include 4–20 mA, pulse, RS485 and HART, depending on the flowmeter model. Turbine flowmeters also offer RS485 Modbus on applicable configurations. Power options include AC 220V, DC 24V or a built-in battery, according to the selected series.

To confirm compatibility with a PLC, DCS or other control system, specify the required signal type, communication protocol and power supply when requesting a quotation.

Manufacturing, Testing and Supply Support

Anhui Tiankang Group was established in 1974 and began large-scale instrument production in 1980. Its group-wide manufacturing operations include five specialized workshops, automated production lines and a 5G digital manufacturing system.

The group has two CNAS-accredited testing laboratories at its headquarters industrial park. These facilities form part of the group's testing resources.

For electromagnetic and vortex flowmeter orders, inspection and calibration arrangements can be discussed according to the selected model and project requirements. Calibration certificates and third-party inspection support can be coordinated where applicable.

Before order confirmation, buyers can specify the required model, measuring range, material configuration, connection standard, output signal, power supply and inspection documents. This helps align the instrument configuration with the pipeline and control system.

Request a Flow Instrument Quotation

To select a suitable flowmeter and receive a quotation from an industrial flowmeter supplier, provide the following information:

  • Measured medium: Liquid, gas or steam, including its composition and conductivity where applicable.
  • Pipeline size: Nominal diameter (DN) and connection requirements.
  • Flow range: Minimum, normal and maximum flow rates.
  • Operating conditions: Working pressure and temperature.
  • Measurement requirements: Required accuracy and measurement output.
  • Installation: Integral, remote or insertion construction, where applicable.
  • Electrical requirements: 4–20 mA, pulse, RS485, HART or Modbus, plus the required power supply.
  • Order details: Required quantity, delivery destination and any inspection or documentation requirements.

Send your operating conditions and technical requirements to discuss the appropriate flowmeter model, configuration and supply options.

As one of the most professional flow instruments manufacturers and suppliers in China, we're featured by quality products and good service. Please feel free to wholesale bulk customized flow instruments made in China here from our factory. Welcome to contact us for pricelist.

Electromagnetic Digital Flow Meter, flow instruments, Vortex Water Flow Meter
Send Inquiry