Our Multipoint RTD is designed to measure temperature at several positions within a tank, reactor or other process vessel. It is commonly used in petroleum storage tanks, petrochemical distillation columns, large chemical reactors and industrial liquid storage equipment. It is suitable for processes where operators need to monitor temperature at different depths rather than at a single point.
The product combines multiple resistance sensing elements in one assembly, with each element measuring temperature at a separate position. Their signals can be sent to a multichannel recorder, PLC or DCS for monitoring. We offer different probe structures to suit the vessel and installation arrangement. The number and position of the sensing points are determined by the required measurement layout, allowing several readings to be collected through one installation point.
Core Advantages
Multiple measurement points through one opening: The integrated structure reduces the number of vessel penetrations required for temperature monitoring.
Independent sensing elements: Each Pt100 element measures its own position, allowing one measurement point to be monitored without changing the others.
Custom insertion depths: Individual probe lengths can be arranged to measure temperature at different liquid levels or process positions.
Different mechanical structures: Armored versions suit environments exposed to vibration or process flow, while assembled versions offer a more economical option for static tanks.


Applications
- Petroleum storage tank temperature profiling.
- Petrochemical distillation column monitoring.
- Large chemical reactor temperature distribution measurement.
- Industrial liquid storage and water tanks.
- Process vessels requiring multiple-depth temperature feedback.
OEM/ODM Customization
We manufacture Multipoint RTD assemblies according to vessel drawings and measurement layouts. Customization includes the number of measurement points, individual insertion lengths, Pt100 accuracy class, probe diameter, protective tube material, flange dimensions, thread connections and terminal enclosure. Each measurement position is confirmed before production because the individual probe lengths are fixed after assembly. Explosion-proof terminal boxes and multichannel transmitter configurations are also available.


Quality Control
We verify each sensing element and check the individual measurement point positions against the approved drawing. Assembly dimensions, wiring connections and resistance-temperature characteristics are inspected before delivery. Our production process is supported by CNAS-accredited laboratories. Each customized unit can be supplied with a measurement position inspection record and applicable calibration documentation.
Product Specifications
|
Parameter |
Armored Multi-Point RTD (WZPKD) |
Assembly Multi-Point RTD (WZPD) |
|
Application |
Petrochemical distillation towers and reactors (vibration and gas-flow erosion environments) |
Atmospheric storage tanks and water tanks (static environments without vibration) |
|
RTD Element |
Pt100 (standard) |
Pt100 (standard) |
|
Temperature Range |
-200°C to 500°C |
-200°C to 500°C |
|
Accuracy Class |
Class A / Class B (IEC 60751) |
Class A / Class B (IEC 60751) |
|
Number of Measuring Points |
Customizable from 2 to 12 points (4/6/8 points are common) |
Customizable from 2 to 12 points (4/6/8 points are common) |
|
Armored Element Outer Diameter |
φ3, φ4, φ5, φ6 mm |
- |
|
Installation Options |
Fixed flange DN50/DN80/DN100, fixed thread M27×2 |
Fixed flange DN50/DN80/DN100, fixed thread M27×2 |
|
Wiring Configuration |
Independent 3-wire connection for each point (standard), 4-wire connection (high accuracy) |
Independent 3-wire connection for each point (standard), 4-wire connection (high accuracy) |
|
Explosion Protection Rating |
Ex d IIB T4 / IIC T6 (explosion-proof version) |
Ex d IIB T4 / IIC T6 (explosion-proof version) |
|
Ingress Protection Rating |
Standard IP65; explosion-proof version IP65 |
Standard IP65; explosion-proof version IP65 |
|
Key Advantages |
Multiple measuring points through a single installation opening, reduced installation costs, independent measurements without mutual interference |
Multiple measuring points through a single installation opening, reduced installation costs, independent measurements without mutual interference |
|
Representative Models |
WZPKD-44C6 (6-point explosion-proof flange type) |
WZPD-24C |
|
Applicable Standards |
IEC 60751, GB/T 30121 |
IEC 60751, GB/T 30121 |
|
Warranty Period |
18 months |
18 months |
FAQ
Q: How many temperature points can one multipoint RTD measure?
A: We offer configurations from 2 to 12 measurement points. Four-, six- and eight-point arrangements are common options.
Q: Can each measurement point have a different insertion length?
A: Yes. Each Pt100 element can be positioned at a specified depth according to the vessel drawing and required temperature profile.
Q: Can the sensor connect directly to a DCS system?
A: Yes. Multichannel transmitter configurations can convert individual resistance signals into 4–20 mA outputs for process control systems.