Our Surface RTD measures the temperature of equipment surfaces without placing a probe inside the process medium. It is used on industrial pipelines, reactor jackets, motor housings, molds and extrusion machine barrels. We also manufacture surface thermocouples for applications that require a different temperature sensing method.
The sensor uses a resistance element that responds to changes in surface temperature. It can be fitted with a flat contact plate, clamp, magnetic base, roller or welded mounting base, depending on the equipment shape and installation method. This makes it a practical choice when users need to monitor surface temperature without drilling into or modifying the equipment.
Core Advantages
Non-invasive measurement: The sensor contacts the equipment surface directly, avoiding the need to insert a probe into the process medium.
Multiple contact arrangements: Clamp-on designs suit pipelines, magnetic versions support temporary checks on ferromagnetic surfaces, and patch sensors fit flat mounting areas.
Pt100 measurement: The resistance-based sensing element supports accurate monitoring in low- and medium-temperature equipment applications.
Flexible lead construction: The braided lead accommodates installation around equipment and helps manage cable movement in industrial environments.


Applications
- External temperature monitoring of steam and process pipelines.
- Chemical reactor jacket temperature measurement.
- Motor and pump bearing housing temperature monitoring.
- Plastic extrusion machine barrel temperature control.
- Industrial mold and metal equipment surface measurement.
OEM/ODM Customization
We supply Surface RTD sensors according to the shape, material and installation requirements of the measured equipment. Custom options include Pt100 accuracy class, contact plate dimensions, clamp diameter, magnetic base, roller structure, lead length, cable protection and terminal connection. Different mounting arrangements can be selected for permanent installation or temporary temperature checks.


Quality Control
We check the Pt100 sensing element, resistance-temperature characteristics, lead connections and assembled probe structure during production. Finished products undergo measurement performance and appearance inspections before shipment. Our instrumentation manufacturing system is supported by CNAS-accredited testing laboratories, and calibration documentation can be arranged according to order requirements.
Product Specifications
|
Parameter |
Surface Thermocouple (WRNM Series) |
Surface RTD (WZPM Series) |
|
Common Thermocouple Types |
K, E, J, T, N |
Pt100 (standard) |
|
Temperature Range |
-200°C to 800°C (welded-base version up to 800°C) |
-200°C to 500°C |
|
Accuracy Class |
Class I, Class II |
Class A, Class B |
|
Probe Design |
Pad-mounted (01), clamp-on (02), magnetic (03), roller (04), welded-base type |
Pad-mounted (01), clamp-on (02), magnetic (03), roller (04), welded-base type |
|
Sheath Material |
304, 316L, GH3030 |
304, 316L |
|
Response Time (T0.5) |
0.5–3 s (thin-film pad-mounted type offers the fastest response) |
0.5–3 s (thin-film pad-mounted type offers the fastest response) |
|
Ingress Protection Rating |
IP65 (waterproof version); Ex d IIC T6 (explosion-proof version) |
IP65 (waterproof version); Ex d IIC T6 (explosion-proof version) |
|
Lead Configuration |
Stainless steel braided armored cable, flexible for bending |
Stainless steel braided armored cable, flexible for bending |
|
Wiring Configuration |
2-wire |
3-wire (standard), 4-wire |
|
Representative Models |
WRNM-02 (clamp-on), WRNM-03 (magnetic) |
WZPM-02 (clamp-on) |
|
Applicable Standards |
IEC 60584, GB/T 16839 |
IEC 60751, GB/T 30121 |
|
Warranty Period |
18 months |
18 months |
FAQ
Q: What is the difference between a surface RTD and a surface thermocouple?
A: A surface RTD uses resistance changes to measure temperature and is commonly selected for accuracy and stability in its operating range. A surface thermocouple is suitable for a wider temperature range, including higher-temperature surfaces.
Q: Can the sensor be installed on different pipeline diameters?
A: Yes. Clamp dimensions and contact structures can be customized according to the pipeline diameter and installation position.
Q: Which mounting type is suitable for temporary measurement?
A: The magnetic version is suitable for temporary contact measurement on compatible ferromagnetic surfaces.
Hot Tags: surface rtd, China surface rtd manufacturers, suppliers, factory, earth resistance meter, Explosion Proof Thermocouple and Explosion Proof RTD, Multi point RTD, temperature sensing instrument, temperature sensors, Wear Resistant Thermocouple and Abrasion Resistant RTD
